500
FLEXware 500
Model: FW500-DC
Description: DC enclosure which mounts at the DC side of one or two FX Series Inverter/Chargers. Supports up to six
terminal bus bars (not including GBB) and up to three shunt assemblies depending on conguration
Includes: Ground bus bar, 500 amp DC shunt assembly, positive bus, breaker mounting hardware, FW-BBUS and enclosure
mounting hardware
Unit Dimensions (H x W x D) Shipping Dimensions (H x W x L) Shipping Weight Enclosure Type
18.2 x 11.4 x 12.1” (46.2 x 29 x 30.7 cm) 14.5 x 13.4 x 20.3” (36.8 x 34.1 x 51.6 cm) 15 lbs. (6.8 kg) Type-1 indoor (IP30)
Model: FW500-AC
Description: AC enclosure which mounts at the AC side of one or two FX Series Inverter/Chargers. Supports six terminal bus
bars and one FW-X240
Includes: Ground bus bar, DIN mounting bracket, communication cable conduit and enclosure mounting hardware
Unit Dimensions (H x W x D) Shipping Dimensions (H x W x L) Shipping Weight Enclosure Type
18.2 x 11.4 x 12.1” (46.2 x 29 x 30.7 cm) 14.5 x 13.4 x 20.3” (36.8 x 34.1 x 51.6 cm) 15 lbs. (6.8 kg) Type-1 indoor (IP30)
The FW500 system utilizes one FW-MP (mounting plate) and a set of the DCA and FW-ACA conduit adapters for each inverter/charger.
DC and AC breakers, Input-Output-Bypass Assemblies and all other additional components sold separately.
FLEXware 500 AC Input-Output-Bypass Assemblies
Field-installable kit for bypassing the AC input to the AC output for inverter maintenance or installation. Also pro-
vides over-current protection.
Model: FW-IOBD-120/240VAC
Includes: Six 60A 120VAC single pole DIN mount breakers, sliding bypass interlock plate, wire and hardware kit
System Rating Bypass Breaker Input Breaker Output Breaker
Split Phase 120/240 VAC Two Poles @ 60 amps 14.4 kW Two Poles @ 60 amps 14.4 kW Two Poles @ 60 amps 14.4 kW
60 amps 14.4 kW
Model: FW-IOBD-120VAC
Includes: Four 60A 120VAC single pole DIN mount breakers, one 60A 120VAC dual pole DIN mount breaker, sliding bypass
interlock plate, wire and hardware kit
System Rating Bypass Breaker Input Breaker Output Breaker
Single-Phase 120 VAC Two Poles @ 60 amps 14.4 kW Two Poles @ 60 amps 14.4 kW Two Poles @ 60 amps 14.4 kW
120 amps 14.4 kW
Model: FW-IOBD-230VAC
Includes: Six 30A 230VAC single pole DIN mount breakers, sliding bypass interlock plate, wire and hardware kit
System Rating Bypass Breaker Input Breaker Output Breaker
Single-Phase 230 VAC Two Poles @ 30 amps 13.8 kW Two Poles @ 30 amps 13.8 kW Two Poles @ 30 amps 13.8 kW
60 amps 13.8 kW
29
500
Integration Hardware