CDA FW250 Manuale Utente Pagina 15

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 40
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 14
• Specications subject to change without notice.
15
The OutBack true sinewave GFX International Series Inverter/Charger is a competitive power solution designed
for applications with lower power demands. Incorporating a DC-to-AC sinewave inverter, battery
charger and AC transfer relay housed within a die-cast aluminum chassis, the International
Series GFX Inverter/Chargers give you the ability to sell solar, wind or hydro power back to
the utility grid while providing instantaneous back-up power in the event of a utility outage.
The GFX International Series built in transfer relay automatically disconnects your
loads from the utility grid and powers them from the inverter in the event of an
outage, allowing you to continue using your solar and battery back-up power,
unlike traditional grid-tie systems. For areas that frequently experience power
instability such as surges, spikes or brownouts, or where standard inverters have
trouble syncing to the utility grid, the GFX International Series grid reconnect
timers have been shortened to reduce overall sell-back downtime and improve
system functionality.
Intelligent multi-stage battery charging prolongs the life of your batteries and
built-in networked communications allow for simultaneous communications of
up to ten OutBack Power components within the system. The exclusive modular
system architecture means that increased power output is just an additional
inverter/charger away. Our GFX International Series uses a sealed chassis that can
operate in the harshest environmental conditions such as high humidity and corrosive salt air.
Inverter/Charger
GFX International Series
* * * NOTE: THIS PRODUCT IS NOT ETL LISTED TO UL1741. NOT INTENDED FOR USE IN THE U.S. OR CANADA.* * *
GFX1312E GFX1424E GFX1448E GFX1312 GFX1424 GFX1548
Nominal DC Input Voltage 12 Vdc 24 Vdc 48 Vdc 12 Vdc 24 Vdc 48 Vdc
Continuous Power Rating at 25° C (77° F) 1300 VA 1400 VA 1400 VA 1300 VA 1400 VA 1500 VA
AC Voltage/Frequency 230 Vac 50 Hz 230 Vac 50 Hz 230 Vac 50 Hz 120 Vac 60 Hz 120 Vac 60 Hz 120 Vac 60 Hz
Continuous AC RMS Output at 25° C (77° F) 5.7 Aac 6.1 Aac 6.1 Aac 10.8 Aac 11.7 Aac 12.5 Aac
Idle Power
Full ≈ 18 Watts ≈ 18 Watts ≈ 18 Watts ≈ 18 Watts ≈ 18 Watts ≈ 18 Watts
Search ≈ 6 Watts ≈ 6 Watts ≈ 6 Watts ≈ 6 Watts ≈ 6 Watts ≈ 6 Watts
90% 92% 93% 90% 92% 93%
Total Harmonic Distortion
Inverting (V)
2% 2% 2% 2% 2% 2%
Selling (A)
<5% <5% <5% <5% <5% <5%
Output Voltage Regulation ± 2% ± 2% ± 2% ± 2% ± 2% ± 2%
Maximum Output Current Peak 28 Aac 28 Aac 28 Aac 56 Aac 56 Aac 56 Aac
RMS 20 Aac 20Aac 20 amps AC 40 Aac 40 Aac 40 Aac
AC Overload Capability
Surge 4600 VA 4600 VA 4600 VA 4600 VA 4600 VA 4600 VA
5 Second 2900 VA 2900 VA 2900 VA 2900 VA 2900 VA 2900 VA
30 Minutes 1800 VA 2000 VA 2000 VA 1800 VA 2000 VA 2000 VA
AC Input Current Maximum 30 Aac 30 Aac 30 Aac
60Aac 60Aac 60Aac
AC Input Voltage Range (Adjustable) 140 to 280 Vac 140 to 280 Vac 140 to 280 Vac 70 to 140 Vac 70 to 140 Vac 70 to 140 Vac
AC Input Frequency Range 45 to 55 Hz 45 to 55 Hz 45 to 55 Hz 54 to 66 Hz 54 to 66 Hz 54 to 66 Hz
DC Input Voltage Range 10.5 to 17.0 Vdc 21.0 to 34.0 Vdc 42.0 to 68.0 Vdc 10.5 to 17 Vdc 21.0 to 34.0 Vdc 42.0 to 68.0 Vdc
Continuous Battery Charger Output 70 Adc 40 Adc 20 Adc 70 Adc 40 Adc 20 Adc
Max DC Current at Rated
Power 130 Adc 70 Adc 35 Adc 130 Adc 70 Adc 37.5 Adc
Warranty Standard 5 year
Weight - kg/lb
Unit
Shipping
Dimensions - H x W x L (cm/in)
Unit
Shipping
22.5 / 49.6
25.6 / 56.4
33 x 21 x 41 / 13 x 8.25 x 16.25
55 x 33 x 56 / 21.75 x 13 x 22
GFX International Series
Vedere la pagina 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 39 40

Commenti su questo manuale

Nessun commento