Weekly Maintenance
Copyright © 2012 EVG 37
4
4
4.3.2 Hydraulic System Upgrade (currently used)
4.3.2.1 Schematics
Without back pressure control
Figure 30 - Hydraulic System without backpressure control
Note:
“Piston up” and “pressure-converter up” are connected and use a pneumatic
pressure of 2bar. A medium separator is used to build up a hydraulic pressure
of 2bar to drive the hydraulic piston up.
The hydraulic-cylinder is a “double-acting” cylinder with hydraulic-function for
up and down motion.