REGULATION OF THE MINIMUM FLAME
This needs to be done only for the oven burner (the grill is a fixed capacity) by acting
on the thermostat.
Considering that in the minimum position the flame must have a length of about 4
mm and must remain lit even with a brusque passage from the maximum position to
that of minimum.
The flame adjustment is done in the following way:
Light the oven burner by turning the knob on position .
Let the oven pre-heat for about 10 minutes, then take the knob to position
(minimum) to operate at by-pass flow.
Remove the thermostat knob and by means of a thin screwdriver pass by the hole in
the facia panel to unscrew of 3 turns the by-pass screw G (fig. 12)
Slowly tighten the by-pass screw G (fig. 12) until you get a flame of 3-4 mm long.
Turn off the burner and reassemble the knob.
After regulation (always with oven hot and the oven door closed) check the stability
of the flame with a passage from the maximum to minimum position.
The grill is a fixed capacity and does not be adjusted.
N.B.: For Liquid gas (G 30/G 31) the screw G must be tightened thoroughly.