Cat: II 2H3+
I
NCREASE OF AIR NECESSARY FOR GAS COMBUSTION (2 m
3
/h x kW)
BURNERS Air necessary for combustion [m
3
/h]
Auxiliary (A) 2,00
Semi-rapid (SR) 3,50
Rapid (R) 6,00
Triple-ring 7,00
Oven (left) 7,40
Grill (left) 5,00
Oven (right) 4,40
Grill (right) 4,00
Auxiliary (A) 1,00 0,30 27 50 - 72 (X) -
Semi-rapid (SR) 1,75 0,45 32 65 - 97 (Z) -
Rapid (R) 3,00 0,75 42 85 - 115 (Y) -
Triple-ring 3,50 1,50 65 95 - 135 (T) -
Oven (left) 3,70 0,75 40 92 fully open 140 5
Grill (left) 2,50 - - 80 fully open - 120 4
Oven (right) 2,20 0,63 38 72 fully open 110 4
Grill (right) 2,00 - - 70 fully open
- 105 2
Nominal
Power
[kW]
Reduced
Power
[kW]
Ø injector
[1/100 mm]
G 30 - 28-30 mbar
G31- 37 mbar
G 20
20 mbar
BURNERS
By-pass
[1/100 mm]
Ø injector
[1/100 mm]
By-pass
[1/100 mm]
Tube ring
opening
[mm]
Tube ring
opening
[mm]
Commenti su questo manuale