CDA hn6110 Specifiche Pagina 24

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 23
24
connection box.
As the appliance is not tted with an accessible plug, a means of
disconnection from the power supply must be must be included in
the fixed insatllation, in accordance with the installation regulations.
The inlet cable must be positioned so that it does not touch any of
the hot parts of the hob or oven.
Caution
This appliance must only be connected to a 230V ~ 50Hz mains
electrical supply.
The connection box is located underneath at the back of the hob
casing. To open the cover use a at screwdriver. Insert it in the slits
to open the cover.
Ensure that a bridge is tted between terminals L1 and L2 and
another bridge between terminal N1 and N2.
Mains electrical voltage: 230Vac, 50 Hz
Total rated electrical consumption: 6.5 kW
Vedere la pagina 23