42
Steam generator Burner ON Burner OFF
MODELS V ignition S1 V maximum S2
Ø Air washer Gas valve GV1-GV2 Nozzles. (Qty=12)
P out (mbar) P out (mbar)
HVG 10/11 B.P. Ve=2000 rpm V=4000 rpm Ø18: T-115082 T-115097 Z-955899
0,3:1,1
-0,8:-0´3
HVG 10/11 Prop. USA-60 Hz " V=4500 rpm " T-115100 "
HVG 10/11 B.P. Australia " " " T-115097 "
HVG 10/11 G.N. Ve=3000 rpm V=4500 rpm Ø20: T-115083 T-115098 Z-956104
1,3:3
-0,9:0,1
HVG 10/11 G.N. USA-60 Hz " " " T-115101 "
HVG 10/11 G.N. Australia " " " T-115098 Z-956109
HVG 10/21 B.P. Ve=2000 rpm V=5500 rpm Ø18: T-115082 T-115097 Z-955899
0,5:1,8
-0,9:-0,3
HVG 10/21 Prop. USA-60 Hz " V=6000 rpm " T-115100 "
HVG 10/21 B.P. Australia " " " T-115097 "
HVG 10/21 G.N. Ve=3000 rpm V=5500 rpm Ø20: T-115083 T-115098 Z-956104
2:4
-0,8:0
HVG 10/21 G.N. USA-60 Hz " V=6000 rpm " T-115101 "
HVG 10/21 G.N. Australia " " " T-115098 Z-956109
Steam generator Burner ON Burner OFF
MODELS V ignition S1 V maximum S2
Ø Air washer Gas valve GV1-GV2 Nozzles. (Qty.=12)
P out (mbar) P out (mbar)
HVG 20/11 B.P. Ve=3000 rpm V=6000 rpm Ø22: T-135035 T-135037 Z-955899
HVG 20/11 Prop. USA-60 Hz " " " T-135040 "
HVG 20/11 B.P. Australia " " " T-135037 "
HVG 20/11 G.N. Ve=3500 rpm V=6000 rpm Ø26,3: T-135036 T-135039 Z-956104
HVG 20/11 G.N. USA-60 Hz " " " T-135041 "
HVG 20/11 G.N. Australia " " " T-135039 Z-956109
HVG 20/21 B.P.
HVG 20/21 Prop. USA-60 Hz
HVG 20/21 B.P. Australia
HVG 20/21 G.N.
HVG 20/21 G.N. USA-60 Hz
HVG 20/21 G.N. Australia
Commenti su questo manuale